41. According to Blondel’s theorem, if a network is supplied using ‘n’ conductors’ the total power is the _________ of the reading of n wattmeters so arranged that a current coil of each wattmeter is in each line and the corresponding pressure coil is connected between that line and a common point.
- Sum
- Product
- Sum of products of two wattmeter’s reading taken together
- Difference
42. The power of an n-phase circuit can be measured by using a minimum of
- n elements
- 2n wattmeter elements
- (n-1) wattmeter element
- (n+1) wattmeter element
43. In a balanced 3-phase 400V circuit, the line current is 115.5 A when the power is measured by two wattmeter method, one meter reads 40kW and the other zero. What is the power factor of the load?
- 1
- 0.5
- 0.6
- 0.8
44. Wattmeter is an instrument which measures
- Instantaneous power
- Average power
- Apparent power
- Reactive power
45. In a 3-phase, 3-wire unbalanced load, power can not be measured by two wattmeters
- TRUE
- FALSE
- Can not be said
- None of these
46. Two wattmeter method for measuring power factor is used for
- balanced load only
- balanced and unbalanced loads
- unbalanced load only
- star connected balanced load only
47. The pressure col of a dynamometer type wattmeter is
- Highly inductive
- Highly resistive
- Purely resistive
- Purely inductive
48. The pressure coil of a wattmeter should be on the supply side of the current coil when
- supply voltage is low
- supply voltage is high
- load impedance is low
- load impedance is high
49. A compensated wattmeter has its reading corrected for error due to the
- frequency
- friction
- power consuned in current coil
- power consumed in potential coil
50. In two wattmeter method of measuring 3-phase power, power factor is 0.5. Then, one of the wattmeters will read
- $\frac{W}{2}$
- zero
- $\sqrt{2}W$
- $\frac{W}{\sqrt{3}}$