1. Notches are used to measure
- velocity
- flow rate
- pressure
- all above
2. For which angle of triangular notch the discharge over it is maximum?
- 45°
- 30°
- 90°
- 60°
3. The discharge over a rectangular notch is
- inversely proportional to H3/2
- directly proportional to H3/2
- inversely proportional to H5/2
- directly proportion to H5/2
4. Which notch is preferred for measuring the low discharges?
- triangular notch
- rectangular notch
- trapezoidal notch
- parabolic notch
5. The discharge through a V-notch varies as
- H
- H1.5
- H0.5
- H2.5
6. The sheet of water flowing through a notch or weir is known as
- Nappe
- Crest notch
- Crested weir
- Crest
7. In any channel, notch is used to measure the following
- discharge
- pressure
- velocity
- static energy
8. Discharge Q in a triangular weir varies as
- H1/2
- H
- H3/2
- H5/2
9. Which notch is preferable for low flow rates?
- Rectangular
- Triangular
- Both Rectangular and Triangular
- None of these
10. In a 90° triangular notch, the error in the estimated discharge for a given head due to an error of 1% in cutting the vertex angle is
- 1 %
- zero
- π/2 %
- π %
11. If H is the head, the discharge through a V-notch varies
- proportional to head (H)
- inversely proportional to angle θ
- inversely proportional to tan θ/2
- proportional to H5/2
12. The discharge through a V-notch varies with the depth of water H as
- H1/2
- H3/2
- H5/2
- H-1/2
13. For maximum discharge over a triangular notch, the angle of the notch should be
- 60°
- 30°
- 120°
- 90°
14. Notch is used for measuring
- velocity through a small channel
- rate of flow through a pipe
- velocity through a pipe
- rate of flow through a small channel
15. Notch is a device used for measuring
- rate of flow through pipes
- rate of flow through a small channel
- velocity through a pipe
- velocity through a small channel
16. The rate of flow through a V-notch varies
- H
- H1/2
- H5/2
- H3/2
17. A triangular notch is more accurate measuring device than a rectangular notch
- for low flow rates
- for medium flow rates
- for high flow rates
- for all flow rates
18. The discharge over a rectangular notch is
- directly proportional to H5/2
- directly proportional to H3/2
- inversely proportional to H3/2
- inversely proportional to H5/2
19. The head over a 90° V-notch increases from 0.20 m to 0.40 m. The ratio of the new discharge to the original discharge is
- 1.414
- 2.000
- 4.000
- more than 4.000
20. The percentage error in the computed discharge over a triangular notch corresponding to an error of 1% in the measurement of the head over the notch, would be
- 2.5
- 2
- 2.2
- 1.5