1. A selection of fuse is based on
- Steady load
- Fluctuating load
- Both (a) & (b)
- None of these
2. The rating of fuse wire is always expressed in
- Volts
- Amperes
- Ampere-volt
- Ampere-hours
3. Consider the following statements and select the current option.
Statement A: When current more than the fixed value flows in the circuit, fuse wire melts.
Statement B: Fuse wire is made up of a low melting point material.
- A and B are true and B is the correct explanation of A
- A and B are true but B is not the correct explanation of A
- A is true but B is false
- B is true A is false
4. HRC fuse provides the best protection against
- Open circuit
- Overload
- Reverse current
- Short circuit
5. Which of the following is used in liquid fuses?
- Transformer oil
- Sulphur hexafluoride
- Distilled water
- Carbon tetrachloride
6. Main function of the fuse is to
- Protect the line
- Open the circuit
- Protect the appliance
- Prevent excessive current
7. For a fuse wire of diameter ‘d’, fusing current is proportional to
- $\sqrt{d}$
- $d^{1.2}$
- $d^{1.5}$
- $d^{3}$
8. If a combination of HRC fuse and circuit breaker is used, the circuit breaker operates
- For low overload currents
- For short-circuit current
- Under all abnormal currents
- Combination is never used in practice
9. A fuse is inserted in
- Neutral
- Earth continuity conductor
- Phase
- Both phase and neutral
10. On what factors does the current carrying capacity of a fuse depend?
- size of fuse wire
- fuse material
- surrounding of the fuse
Choose the correct answer from the options given below.
- Only I
- Only I and III
- Only II and III
- I, II and III
11. The function(s) performed by fuse is (are)
- to carry the normal working current safely without heating
- to break the circuit when current exceeds the limiting current choose the correct
Answer from the options given below.
- Only (i)
- Only (ii)
- Both (i) and (ii)
- Neither (i) nor (ii)
12. A fuse is never inserted in
- Neutral wire
- Negative of DC circuit
- Positive of DC circuit
- Phase line
13. Consider the following statements
HRC fuse as compared to a rewireable fuse has
- No ageing effect
- High speed of operation
- High rupturing capacity
- Only A and B
- Only B
- Only B and C
- A, B and C
14. The fusing current depends on
- Diameter of fuse wire
- Number of wire
- Length of the fuse wire
- All of the above
15. The least expensive protection for over-current in a low voltage system is
- Rewirable fuse
- Isolator
- Circuit breaker
- Air-break switch
16. A fuse is provided in an electric circuit to
- Reduce the power consumption in the circuit
- Limit the current in the circuit
- Safeguard the circuit against heavy current
- Increase the current in the circuit
17. HRC fuse has rupturing capacity of capability______ in comparison with a circuit breaker.
- Equal
- Greater than
- Less than
- None of these
18. For better performance the suitable one is
- Open type fuse
- Kit-kat fuse
- HRC fuse
- Cut-outs
19. The function of the fuse in an electrical circuit is to protect
- Insulation resistance
- Over loading of the circuit
- Over voltage
- Insulation resistance and excess voltage
20. The characteristics of the fusing element should be a wire of
- Low resistance
- High resistance
- High melting point
- Low resistance & low melting point